Over the years, AcobiaFLUX has developed a number of solutions to specific customer problems. But problems are not always unique – we often identify similar needs at several different locations. This has laid the ground for many of our products. When we cannot find an existing system or product that solves our customer’s problem, we create one ourselves.
The knowledge, ability and interest in creating innovative systems is the basis for our business. Our solutions are the result.
Effective alarm management, alarm history & statistics
AX Alarm Manager is a complete system for fast, secure and effective alarm management. AX Alarm Manager gives you access to all the functions you would expect from an alarm management system – including real-time management, historic follow-up and traceability.

Latest news
2015-04-09
AX Alarm Manager 1.3.15100
AX Alarm Manager is now 1.3.15100 available for download. The new version includes among others the following:
- Citect 7.40
Support for use together with Citect 7.40. - Customisable
Extended possibilities for customisation of text and symbols. - AX Event Manager (optional)
Add-on module for AX Alarm Manager used for presentation of events other than alarm events.
More news
2011-10-14
AX Alarm Manager 1.2.11286
AX Alarm Manager is now 1.2.11286 available for download. The new version includes the following:
- Filter manager
The filter manager is updated to make it possible and easier to create even more advanced filters. - Privileges
AXAM now integrates with the Citect alarm privileges. The operator can only see and manage the alarms Citect permits them to. - Labels
This is a new concept where the user can put labels on alarms and events. The labels can then be used in filter expressions to create custom lists and diagrams.
2010-11-02
AX Alarm Manager 1.2.10306
X Alarm Manager 1.2.10306 is now available for download. The new version includes the following:
- Certification
AXAM is certified by Microsoft. - Start page
A start page can be displayed on startup that summarizes the current alarm situation and provides an overview of the alarm history for the last day. - Norwegian translation
AXAM is now available in Norwegian. - Plant copies
Ability to run AXAM against any number of plants with the same tag set.
2010-06-04
Demo version of AX Alarm Manager 1.2 is now available for download.
2010-02-10
Demo version of AX Alarm Manager 1.1 is now available for download.
2009-10-19
High resolution screen shots are now available under “Screen shots”.
2009-10-12
Demo version of AX Alarm Manager is available for download.
Try AX Alarm Manager for 2 hours!
Try AX Alarm Manager now for free!
Fill in your details below to register, and you will be able to download a demo version of AX Alarm Manager for free. The demo version gives you the opportunity to test a client for 2 hours with full functionality. You must then pause for 2 hours before another 2-hour test key will be made available.
Fill in the form below and you will receive a link to the download page via email. The link will be available for one hour!
AX Alarm Manager Screenshots
Effective alarm management, alarm history & statistics
AX Alarm Manager is a complete system for fast, secure and effective alarm management. AX Alarm Manager gives you access to all the functions you would expect from an alarm management system – including real-time management, historic follow-up and traceability.
Show screenshots
Alarm management
Alarms are presented in clear lists, which clearly state the status of each alarm. It is easy to sort the lists into one or several columns, and you can also choose to show or hide columns as necessary. Each list that is opened is shown in its own tab, which makes it simple to navigate between the lists you are currently working with.
The alarms are managed via right-click menus and the toolbar. You can write comments for each alarm, and attach files containing further information about the alarm, suggested responses, contact lists etc. This makes it easy to distribute information between users of the system. It is also very easy to show the history for alarms by choosing “Show alarm history”.
In order to simplify working with many alarms, AX Alarm Manager has Groups. Groups allow the user to carry out operations on a group of alarms instead of individual alarms. In other words, you can block or reset a whole group of alarms with one simple click. You can create your own group under “My Groups” or use one of the pre-defined Groups.
History
All alarm events are stored and displayed in the event logs under the History section. You can use one of the predefined event logs, or create your own filters for the event logs, which only show the events you are interested in. In the event logs you can also see which user reset or blocked an alarm and if they wrote any comments in connection with the event.
Statistics
In the Statistics section there is a selection of different graph types to choose from. In the top menu there is a Top List of the most common alarms in the system, showing how many times they have been activated. It is also possible to create a Top List, which instead of being ordered by the number of alarm occurrences will show the total time that an alarm has been active. As with alarm lists and event logs, you can create your own graph types which filter out all information that is irrelevant to you.
AX Carat
Full control over disturbances and undesired downtime.
AX CARAT is a cost-effective tool for measuring, analyzing and preventing undesired downtime in the production.
AX Citect Studio 2.0
Streamline and secure the quality of your Citect site.
AX Citect Studio is designed to save time in environments where users work with multiple or very large Citect projects.
LISTEC
AX Link2Listec
The complete package for fire protection in demanding industrial and technical environments, easily integrated with your current systems. The entire range is covered – from sensors to databases for analysis and history, and with full traceability of manual changes, values, alarms and other events. (NB: Product sheet in Swedish).
LISTEC
LIST Controller
The LIST®controller , with its ARM9TM embedded processor and two secondary processors, is the new generation control and evaluation unit for LIST® systems. The three processor system allows rapid and reliable recognition, detection and signalling of fires. One or two sensor cable lengths or group of sensor cable branches may be connected to the controller, which performs the cyclic addressing of all connected sensors to receive actual temperature values with a high resolution and an exceptional recurring accuracy.
LISTEC
SEC 20 Sensor Cable
The hermetically sealed sensor cable contains small hybrid circuits which, depending on the application, are placed at selectable intervals. The hybrids, which contain an integrated circuit with a defined address and a semiconductor temperature sensor, are electrically connected by a flat flexible cable.
Gurusoft Report – EOS
Reduce energy consumption
With accurate measurement data it’s easy to see where the greatest energy savings are to be made. Gurusoft Report – EOS is a modern system for collection and evaluation of energy data which helps to make energy use more efficient.
Price List Products
AX Professional Services
AcobiaFLUX has a long history of working with Citect and Citect-related products. We deal with Industrial IT & Automation in many business sectors and we are knowledgeable and proficient in many types of control and SCADA systems. In 2008, AcobiaFLUX was named the world’s leading Citect integrator.
info@acobiaflux.se
Our locations